EasyManuals Logo

BluStream Multicast ACM200 User Manual

BluStream Multicast ACM200
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
ACM200 USER MANUAL
20 www.blustream.co.uk / www.blustream.com.au
Web-GUI - Transmitters - Actions
The 'Actions' button allows for
advanced features of the units to be
accessed and configured.
Features of the Actions menu include:
1. Name - Transmitter names can be amended by entering a name into the free-form text box. Please note: this is
limited to 16 characters in length, and some special characters may not be supported.
2. Update ID - the ID of a unit is set as default to the same number as the last 3 digits of the units IP address i.e.
Transmitter number 3 is assigned an IP address of 169.254.3.3 and will have an ID of 3. Amending the ID of the
unit is not normally recommended.
3. CEC Pass-through (On / O) - allows for CEC (Consumer Electronic Command) to be sent through the Multicast
system to and from the source device connected to the Transmitter. Please note: CEC must be enabled on the
Receiver unit also for the CEC commands to be sent between. Default setting for this feature is O. If more than
one Blustream Receiver is viewing a Transmitter, the CEC is passed between all devices. Because of this it is
advised to leave CEC disabled on all products unless required.
4. Front Panel Display (On / O) - use this to enable / disable the dual 7-segment LED displays on the front of the
Transmitter. The front panel display of the Multicast unit will automatically time-out aer 90 seconds and turn
o.
5. Front Panel Power LED Flash (On / O / On 90 Seconds) - will flash the power LED on the front panel of
the Transmitter to help identify the device following auto configuration. Options are: flash the power light
continuously, or flash the LED for 90 seconds before the LED goes back to being permanently lit. Please note:
the front panel LED's will automatically time-out aer 90 seconds with the front panel display. Press one of the
CH buttons to wake the unit.
6. Copy EDID - see page 21 for further information on Copy EDID.
7. Serial Settings - turn on serial 'Guest Mode' and set the individual serial port settings for the device (i.e. Baud
Rate, Parity etc).
8. Preview - displays a pop-up window with live a screen grab of the source device connected to the Transmitter.
9. Reboot - reboots the Transmitter.
10. Replace - used to replace an oline Transmitter. Please note: the Transmitter to be replaced must be oline
for this feature to be utilised, and the new Transmitter must be a factory default unit with default IP address:
169.254.100.254.
11. Remove from Project - removes the Transmitter device from the current project.
12. Factory Reset - restores the Transmitter to its original default settings and sets the IP address to:
169.254.100.254.

Other manuals for BluStream Multicast ACM200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BluStream Multicast ACM200 and is the answer not in the manual?

BluStream Multicast ACM200 Specifications

General IconGeneral
BrandBluStream
ModelMulticast ACM200
CategoryControl Unit
LanguageEnglish