ENERGY CENTER SETTINGS
Energy Center Settings can be used to adjust Automatic Generator Start usage.
Battery Levels
Used to nominate the minimum battery voltage level which
will automatically start battery charging from the generator.
Battery charging will stop when the target voltage is
reached.
AGS monitors both system voltage and RV battery voltage
and uses the greater of the two to determine whether to turn
the generator on or off.
Use AGS to Support
This setting is used to determine if AGS will support battery
levels, climate or both.
9 Battery Levels: the generator will turn on and run until
the battery is charged to the set target voltage.
9 Climate: the generator will turn on so the air conditioner
can run. If the temperature of the RV climbs above the set
point in the Climate screen, AGS will turn the generator
on and the generator will run until the temperature
comes back down to the set point.
9 Both: the generator will turn on and run until both the
battery and climate levels reach the set points.
41