3.0 Important Safety Information
WARNING: The appearance of this symbol indicates the proximity of
an exposed high voltage area. Please follow all directions carefully for
your personal safety. You must read the following safety information
carefully before working on the printer.
As a safety precaution, all service to the printer should be done by qualified persons with
power off and the AC cord unplugged from the printer. Following any procedure requiring the
removal of covers and/or doors, please verify that they have been properly attached and
fastened prior to operating the printer.
WARNING: Provide an earthing connection before the mains plug is connected to the mains. And,
when disconnecting the earthing connection, be sure to disconnect after pulling out the mains plug
from the mains.
WARNING: Power Cord Set: This must be approved for the country where it is used:
U.S.A. and Canada
The cord set must be UL-approved and CSA certified.
The minimum specification for the flexible cord is:
No. 18 AWG
Type SV or SJ
3-conductor
The cord set must have a rated current capacity of at least 10A.
The attachment plug must be an earth-grounding type with a NEMA 5-15P
(15A, 125V) or NEMA 6-15P (15A, 250V) configuration.
WARNING: The appliance coupler (the connector to the unit and not the wall plug) must have a
configuration for mating with an EN60320/IEC320 appliance inlet.
WARNING: The socket outlet must be near to the unit and easily accessible.