Trouble shooting
BOMAG124 BMP 8500
control sender in operating mode for this function
test.
For testing the spiral cable switch the operating
mode switch to cable operation, connect the spiral
cable to the sender and start the machine.
If the engine starts, the spiral cable is OK.
System information
Setting the remote control type
Fault log
BOSS safety system
Input code Description of display function Display values
0555 Software Version
Shows the software version number.
3-digit version number
0561 Supply voltage
Shows the voltage value
Display value = voltage in V
Input code Description of display function Display values
0660 Switches on function "Set remote control
type"
See adjustment instructions
0661 confirms the entered remote control type See adjustment instructions
0662 Preselect radio remote control, default set-
ting
See adjustment instructions
Input code Description of display function Display values
0700 Switch on function „Show stored faults“ See adjustment instructions
0701 Switch off function "Show stored faults" See adjustment instructions
0710 Delete all stored faults See adjustment instructions
Input code Description of display function Display values
6000 Enable service mode 6000
6001 Service mode active, machine travels for
15min. without activated BOSS safety sys-
tem.
Attention: Only for servicing purposes!
6001 = service mode active
6002 Service mode inactive