Every 250 operating hours
BOMAG 73BMP 8500
Cleaning with cold cleansing agent
Protect electrical equipment such as generator
and starter against the direct water jet.
l Spray engine and cooler with a suitable
cleansing agent, e.g. cold cleanser, let it soak
in for a while and spray it off with a strong wa-
ter jet.
l Run the engine warm for a while to avoid cor-
rosion.
5.15 Change the oil in the vibra-
tor shaft housing
Change the oil at operating temperature. For
this purpose run the machine approx. half an
hour with vibration.
Catch running out oil and dispose of environ-
mentally.
Danger of injury!
Do not step under suspended loads.
Fig. 104
l Lift the machine up and support it safely (Fig.
104).