EasyManua.ls Logo

Bomag BMP 8500 - Safety Inspection for the Radio Remote Control

Bomag BMP 8500
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
BOMAG 49BMP 8500
Fig. 75
l Insert the power pack into the battery charger
(Fig. 75).
Fig. 76
l Connect the battery charger to a power source
(Fig. 76).
The two light emitting diodes on battery charger
and mains unit must light up.
i
Note
The power pack recharging time is approx. 6
hours.
When charging is completed the green LED on the
charger will start to flash.
4.12 Safety inspection for the ra-
dio remote control
This safety inspection must be performed regularly
once every week, especially after longer breaks.
!
Danger
Danger of injury!
Make sure that there are no persons within the
danger zone.
!
Caution
Rests of mortar or concrete may restrict the
movement of the travel control levers. Check
from time to time (with the sender switched
off!) whether both travel control levers return
reliably to their neutral position when being re-
leased.
Fig. 77
l With the transmitter switched off actuate and
hold one of the travel levers 1 or 2 (Fig. 77).
l Switch on the transmitter and try to start the
diesel engine.
The diesel engine must not start.
l Return the travel lever to neutral position (rest
position).
l Start the engine and actuate the travel lever
again.
The functions must now work as usual.
l Operate the emergency stop switch (3).
The machine must stop and the engine must be
shut down.