EasyManua.ls Logo

Bomag BMP 8500 - Switching the Vibration on and off; Automatic; Safety Inspection for the Cable Remote Control

Bomag BMP 8500
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
BOMAG 39BMP 8500
4.6 Safety inspection for the ca-
ble remote control
This safety inspection must be performed regularly
once every week, especially after longer breaks.
!
Danger
Danger of injury!
Make sure that there are no persons within the
danger zone.
!
Caution
Rests of mortar or concrete may restrict the
movement of the travel control levers. Check
from time to time (with the sender switched
off!) whether both travel control levers return
reliably to their neutral position when being re-
leased.
Fig. 43
l With the machine shut down actuate and hold
one of the travel levers 1 or 2 (Fig. 43).
l Try to start the diesel engine.
The diesel engine must not start.
l Return the travel lever to neutral position (rest
position).
l Start the engine and actuate the control lever
again.
The functions must now work as usual.
l Operate the emergency stop switch (3).
The machine must stop and the engine must be
shut down.
4.7 Switching the vibration on
and off
!
Danger
Risk of damage!
When compacting with vibration you must
check the effect of nearby buildings and un-
derground supply lines (gas, water, sewage,
electric power), if necessary stop compaction
with vibration.
Do not activate the vibration on hard (frozen,
concrete) ground. Danger of bearing damage!
Automatic
Fig. 44
l Set the vibration switch (Fig. 44) to "Automat-
ic".
Fig. 45
l Choose the amplitude (Fig. 45).