Operation
BOMAG44 BMP 8500
All normal work functions can only be operated
from a defined neutral position, i.e. the respective
control elements must be in rest position when
switching the sender on. If this is not true, the en-
gine cannot be started.
l Strap the transmitter to your body, adjust the
belts accordingly.
Fig. 60
l If necessary unlock the emergency stop switch
(Fig. 60).
Fig. 61
l Set the vibration toggle switch (Fig. 61) to po-
sition "0".
Starting the engine
Before starting the engine both travel levers and
the vibration control lever must be in rest position
(neutral).
The radio remote control is equipped with a re-
start lock.
Fig. 62
l Switch on the ignition (Fig. 62).
The green control light on the transmitter starts to
flash and a buzzer signal sounds. The transmitter
is ready for operation.
After a period of approx. 5 to 10 seconds the signal
horn on the machine starts to sound.
The machine is now ready for operation.
Fig. 63
l Press the start button to start the engine (Fig.
63).
Run the engine warm for a short while before start-
ing work.