Interfaces, Ports & Connectors
65
1070 073 822-104 (02.06) GB
X57 Serial port used as an RS-485/422, IPC: alternative to COM2
IPC300: alternative to COM1
This port can be assigned only in the event that the COM2 port (IPC) or
COM1 port (IPC300) is not used. Parallel operation is not possible.
The X57 interface is not suitable as a connection for the touch screen con-
troller of a connected control panel.
Male DB-9 connector
Type: RS-485/422
Cable length: Max. 15 m
Cable type: Screened, min. cross-section 0.14 mm
2
Transmission rate: Max. 115200 bps
Handshake: Hardware and software handshake (X
ON
, X
OFF
)
Interrupt (IRQ): 3 (IPC), 4 (IPC300)
I/O address: 2F8H (IPC), 3F8H (IPC300), AUTO (recommended)
BIOS preset: IPC: Onboard Serial Port 2: AUTO
IPC300: Serial Port A: Enabled
To peripheral
devices
1
2
3
4
Screen applied to metal
shell of connector
5
6
7
8
9
1
5
69
RS485/422
DCD
RXD−
TXD−
GND
RI
DTR
DSR
RXD+
TXD+
X57
Assignment as an RS-485/422:
(For more information on pin assignment, see Page 63)
DCD as for RS-232
RXD, RXD+ Receive Data. Line on which data is received.
TXD, TXD+ Transmit Data. Line on which data is transmitted to peripheral.
DTR as for RS-232
DSR as for RS-232
GND as for RS-232
RI as for RS-232
Screen as for RS-232
Settings
The S3 DIP switch can be used to configure the X57 interface as an RS-485
or RS-422:
D X57 = RS-485 Switch 3 set to ON = TXD is controlled via RTS.
Also, for 2-wire operation, TXD+ must be bridged
with RXD+, and TXD with RXD.
D X57 = RS-422 Switch 3 set to OFF = TXD always enabled.
1 2345678
ON
OFF
S3
Location of S3: IPC300 = externally accessed, see diagram on page 62
IPC = see diagram on page 612.