70 en | How to Set Up the Access Easy Controller 2.1 and the Computer Access Easy Controller 2.1
2018.11 | 1.0.6 | F.01U.122.796 Hardware Installation Manual Robert Bosch (SEA) Pte Ltd
14 How to Set Up the Access Easy Controller 2.1 and the
Computer
This chapter provides the basic setup and configuration details of the AEC2.1 system. It is to
be used together with the AEC2.1 Software Manual for a complete configuration of the
system.
14.1 Overview
This section describes the steps required to connect the AEC2.1 system to the customer's
network. It also summarizes the configuration steps needed on a computer for the computer
to be able to connect to the AEC2.1.
Notice!
AEC2.1 is for indoor use only and the system must be installed indoors within the protected
premises.
AEC2.1 Set-up
All AEC2.1 are shipped from the factory with default IP address of 192.168.0.41. Before the
controller can be connected to the customer's network, its IP address will need to be changed
to fit into the customer's network configuration.
If the controller is going to be connected directly to a stand-alone computer on its own private
network, the controller's default address need not be changed. All that will be necessary is to
configure the computer's network settings so that it has an address on the same network as
the controller
For initial setup of the AEC2.1, a Notebook or Desktop computer will be required. The
computer used for the controller setup must have a 10/100Base-T Ethernet card installed in it,
and must run a WindowsXP/Vista or Mac operating system. The computer must also have a
functional Web browser program, such as Microsoft Internet Explorer, version 7.0.
1. Configure the computer that is to be used for setting the controller's IP address so that it
has an IP address on the same 192.168.0 network as the controller. We suggest you set
the computer's IP address to 192.168.0.40, and the subnet mask to 255.255.0.0.
(If you are not sure how to change a computer's network settings, refer to Appendix A
How to Install & Set the TCP/IP Address on a PC, page 101).
2. Connect the AEC2.1 to the computer using a standard Cat-5 crossover cable (Beige Cat-5
cable) as shown below.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Access Easy Controller 2.1 and is the answer not in the manual?

Bosch Access Easy Controller 2.1 Specifications

General IconGeneral
BrandBosch
ModelAccess Easy Controller 2.1
CategoryController
LanguageEnglish

Related product manuals