96 en | Restoring a Backup Copy of Database to the Access Easy Controller 2.1 Access Easy Controller 2.1
2018.11 | 1.0.6 | F.01U.122.796 Hardware Installation Manual Robert Bosch (SEA) Pte Ltd
16 Restoring a Backup Copy of Database to the Access
Easy Controller 2.1
This chapter explains the necessary steps to restore a copy of the controller's database from a
backup stored on the computer. This chapter helps recover the customer's database without
the necessity of complete re-entry. It would be used only under the following circumstances:
The controller's CPU board has been replaced due to a hardware failure.
To install a software upgrade in an operational controller
In both instances, it is desirable to reinstall the customers' existing database, rather than re-
entering the complete database.
16.1 Tools Needed
Computer with network card and Windows operating system
Connectivity between the computer containing the database and the controller through
the network or directly by use of a crossover cable
16.2 Before Starting the Update
1. Log on to the controller.
2. After logging on, select System > Network Settings and note the IP addresses and
Remote PC addresses and hostnames listed under the section heading Remote PC
Addresses. For security reasons, only a computer with an IP address matching one of the
three shown in this section will be allowed to make the FTP connection necessary to
recover the controller database.
3. If the IP address of the computer to be used for database recovery does not match one of
the three listings shown in the database, then the connection will be denied. In that case,
it is necessary to change the settings of either the computer or the controller's database
so that they match. This should be done before proceeding to the recovery procedure. If
the controller database is changed, save the changes before proceeding.
16.3 Recovering Controller Database from a Windows Computer
1. Log into AEC2.1 and select System > Advance Settings > Firmware upgrade tab.
2. Click the browse button to browse for the file you wish to upload. Example, if you are
uploading the backup system database, select the db_tar.gz from your local directory.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Access Easy Controller 2.1 and is the answer not in the manual?

Bosch Access Easy Controller 2.1 Specifications

General IconGeneral
BrandBosch
ModelAccess Easy Controller 2.1
CategoryController
LanguageEnglish

Related product manuals