EasyManua.ls Logo

Bosch Access Easy Controller 2.1 - Page 99

Bosch Access Easy Controller 2.1
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Access Easy Controller 2.1 Entry and Arm/Disarm Reader | en 99
Robert Bosch (SEA) Pte Ltd Hardware Installation Manual 2018.11 | 1.0.6 | F.01U.122.796
Notice!
There is an additional setting available which is the Door Buzzer. When a reader is configured
as an Entry and Arm/Disarm reader, the buzzer control for the reader will need to be rewired
to a spare output on the 4-Reader board. See the wiring diagram below for an example on
Reader1 wired as an Entry and Arm/Disarm reader.
9. Complete the rest of the setup as per a normal door access reader.
10. You need to configure the cardholder to be able to arm/disarm the reader. Refer to
AEC2.1 software manual for configuring an Arm/Disarm card.
11. The section below shows the wiring requirement of Entry and Arm/Disarm Reader for a
HID reader.
Notice!
Refer the software manual for more information on the door settings.