EasyManua.ls Logo

Bosch PRAESENSA - Technical Data

Bosch PRAESENSA
166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
80 en | Installation wiring PRAESENSA
2021.12.21 | V0.15b | F.01U.402.882
Underwriters Laboratories Listing Document (ULLD)
Bosch Security Systems B.V.
3.7.13 Technical data
Electrical
Power transfer
Mains power supply input
Rated input voltage range
Frequency range
Maximum input current
120VRMS
60Hz
10A
Battery power supply input
Nominal DC input voltage
Maximum current
Under-voltage protection
12V
90A
<9V
Battery charger
Nominal charging current
Maximum charging current
Nominal float voltage
8.5A
8.8A
13.5V
Regulated 24VDC output
Nominal DC output voltage
Maximum continuous current
Maximum peak current
24V
0.7A
0.9A
Power over Ethernet (PoE 1‑2)
Nominal DC output voltage
Standard
Maximum PD load
48V
IEE802.3af (mode B)
12.95W
Power consumption
Mains powered
Active mode, all outputs loaded
Battery powered
Active mode, all outputs loaded
<1000W
<1000W
Control interface
Control input contacts (1-8)
Principle
Galvanic isolation
Minimum hold time
Maximum voltage to ground
Contact closure
No
100ms
24V
Control output contacts (1-8)
Principle
Galvanic isolation
Maximum contact voltage
Maximum contact current
Maximum voltage to ground
Contact switch over
(Relay SPDT)
Yes
110VDC, 125VAC
1A
500V