ctrlX SAFETY | Device type SAFEX-C.15 67/83
DOK-XSAFE*-SAFEX-C.1XC-IT03-EN-P, Edition 03, Bosch Rexroth AG
ctrlX SAFETY
link
Tabelle 59: ctrlX SAFETY
link
–LED
ctrlX
SAFETY
link
(PF42)
Color Flashing pattern Meaning
- Off No voltage supply
Green Flashing The bus is in the start-up phase
Green Permanently illuminated The connection is working without
errors - cyclic operation
Red Permanently illuminated Incorrect bus operation during
startup or incorrect data
exchange
Inputs and outputs
Tabelle 60: Input/output LED
I/O Color Flashing pattern Meaning
- Off Inputs and outputs are inactive,
LOW logic status
Green Permanently illuminated Inputs and outputs are activated,
HIGH logic status
Tabelle 61: Input/output status
I/O Logic status Level Meaning
LOW - 3V ≤ U
LOW
≤ 5 V Inputs and outputs are inactive
HIGH 15V ≤ U
HIGH
≤ 30 V Inputs and outputs are activated