Code Name Setting Range Default Min. Attri.
F2.00 Analog input AI1
0: No function assigned from ASF
1: Pressure command
2: Pressure feedback
3: Flow command
4: Oxygen feedback (for myCro)
0 - Stop
F2.01 Analog input AI2 2 - Stop
F2.02
External analog input EAI
(-10V...10V, 4...20mA)
0 - Stop
F2.03
External analog input EAI2
(-10V...10V, 4...20mA)
0 - Stop
F2.04
Pressure command corre-
sponding to 5V, 10V or
20mA
0.1...1,000.0 bar 10.0 0.1 Stop
F2.05
Pressure command null off-
set in V or mA
0.0...5.0 V, mA 0.0 0.1 Stop
F2.06
Pressure feedback corre-
sponding to 5V, 10V or
20mA
0.1...1,000.0 bar 100.0 0.1 Stop
F2.07
Pressure feedback null off-
set in V or mA
0.0...5.0 V, mA
4.0
(mA)
0.1 Stop
F2.08
Flow command correspond-
ing to 5V, 10V or 20mA
1...5,000 rpm 400 1 Stop
F2.09
Flow command null offset in
V or mA
0.0...5.0 V, mA 0.0 0.1 Stop
Tab. 6-1: Analog input parameter list
As the default FcP 5020 configuration, analog input AI2 [F2.01 = 2] is configured
as the pressure feedback input. Analog input AI1 or EAI/EAI2 has no preassigned
configuration by the FcP 5020.
The analog inputs F2.00...F2.03 are mutually exclusive, which therefore do not
allow for any identical setting (except 0) between the parameters. When a re-
peated non-zero value entered, the former will reset to 0 automatically, i.e. the
last entered takes effective.
For broken wire protection of analog input, please check the following table for
setting range of E1.61. For more information please refer to EFC 5610 converter
document (R912005856 or R912005854).
Code
Name Setting Range Default Min. Attri.
E1.61 Broken wire protection
0: Inactive
1: Warning
2: Error
0 - Stop
Tab. 6-2: Parameter E1.61 for broken wire protection
Wire broken monitoring function for all analog inputs can be activa-
ted by E1.61. Default value of E1.61 has been set to 0 in FcP 5020
and 2 in CytroPac default setting.