8.7 Monitoring Parameter
Name Description Setting range
d0.80 ASF status word * 0x0000...0xFFFF
d0.81 Pressure command 0.0...1,000.0 (0.0...1,000.0 bar)
d0.82 Pressure feedback 0.0...1,000.0 (0.0...1,000.0 bar)
d0.83 Flow command -5,000...5,000 (-5,000...5,000 rpm)
d0.84 Effective speed command -5,000...5,000 (-5,000...5,000 rpm)
d0.85 Reserved -
d0.86 Reserved -
d0.87 Reserved -
d0.88 Warning type
0: No warning
1: Pressure feedback exceed limit
2: Pressure command exceed limit
3: Flow command exceed limit
4: Oil filter warning
5: Oil level warning
6: Oil temperature warning
7: Oil change warning
8: Reserved
9: Pump thermal protection warning
10: Pump power limitation warning
11: Oxygen too high
12: System pressure too low
d0.89 Error type
0: No error
1: Pressure feedback exceed pump limit
2: Pressure sensor error
3: Parameter setting error
4: Oil filter error
5: Oil level error
6: Oil temperature error
7: Oil change error
8: Oil level or temperature error
9: Pump thermal protection error
Tab. 8-6: Monitoring parameter
* For detail information of d0.80 ASF status word please reference tab. 9-4 "ASF
status word d0.80 definition" on page 77.