8.3 Group F2: Input and Output Parameter
Code Name Setting range Default Min. Attri.
F2.00 Analog input AI1
0: No function assigned from ASF
1: Pressure command
2: Pressure feedback
3: Flow command
4: Oxygen feedback (for myCro)
0 - Stop
F2.01 Analog input AI2 2 - Stop
F2.02
External analog input EAI
(-10V...10V, 4...20mA)
0 - Stop
F2.03
External analog input EAI2
(-10V...10V, 4...20mA)
0 - Stop
F2.04
Pressure command corre-
sponding to 5V, 10V or 20mA
0.1...1,000.0 bar 10.0 0.1 Stop
F2.05
Pressure command null offset
in V or mA
0.0...5.0 V, mA 0.0 0.1 Stop
F2.06
Pressure feedback corre-
sponding to 5V, 10V or 20mA
0.1...1,000.0 bar 100.0 0.1 Stop
F2.07
Pressure feedback null offset
in V or mA
0.0...5.0 V, mA
4.0
(mA)
0.1 Stop
F2.08
Flow command correspond-
ing to 5V, 10V or 20mA
1...5,000 rpm 400 1 Stop
F2.09
Flow command null offset in V
or mA
0.0...5.0 V, mA 0.0 0.1 Stop
Bosch Rexroth AG
FcP 5020 Parameter List
FcP 5020
66/83
DOK-RCON03-FCP5020****-QU04-EN-P