7.11.3 LED Flash Showing Converter Status
Code Name Setting range Default Attri.
F2.36 DO1 output 0: No function assigned from ASF
1: Converter warning
2: Green CytroPac flashing LED
3: Red CytroPac flashing LED
4: Oxygen too high (for myCro)
5: Pressure too low (for myCro)
-
Run
F2.37 EDO output Run
F2.38 EDO2 output
0: No function assigned from ASF
1: Converter warning
2: Green CytroPac flashing LED
3: Red CytroPac flashing LED
4: Oxygen too high (for myCro)
5: Pressure too low (for myCro)
6: Degas/gas valve control (for my-
Cro)
Run
Tab. 7-27: Parameter list of LED flash function
With active CytroPac functionality, the output is automatically configures to con-
trol the LED flash function. For normal status the light is always green, for warn-
ing condition the light will flash between green and yellow, and for error condi-
tion flash between red and yellow. The flash time of the yellow light represents
the warning / error type. More details refer to the following figure.
FcP 5020
Bosch Rexroth AG
Block Diagram of Main Functions
DOK-RCON03-FCP5020****-QU04-EN-P
55/83

Table of Contents