8.2 Group F1: Quick Start Parameter
Code Name Setting range Default Min. Attri.
F1.00 ASF parameter initialization
0: Inactive
1: Restore to FcP default set-
tings
2: Deactivate ASF
0 - Stop
F1.02 Control mode
0: p/Q control
1: Flow control
2: Pressure control
0 - Stop
F1.03 Pressure command source
0: Depend on the value of
F1.04
1: Select by digital input (F1.04
shows status)
2: Analog input
3: Communication
0 - Stop
F1.04 Pressure command selection
0: Pressure command digital
setting 0
1: Pressure command digital
setting 1
2: Pressure command digital
setting 2
3: Pressure command digital
setting 3
0 - Run
F1.05
Pressure command digital set-
ting 0
0.0...1,000.0 bar 10.0 0.1 Run
F1.06
Pressure command digital set-
ting 1
0.0...1,000.0 bar 10.0 0.1 Run
F1.07
Pressure command digital set-
ting 2
0.0...1,000.0 bar 10.0 0.1 Run
F1.08
Pressure command digital set-
ting 3
0.0...1,000.0 bar 10.0 0.1 Run
F1.11 Flow command source
0: Depend on the value of
F1.14
1: Analog input (positive / nega-
tive)
2: Communication
3: Select by digital input (F1.14
shows status)
0 - Stop
F1.12 Flow command digital setting 0...5,000 rpm 400 1 Run