7.12 myCro Configuration
7.12.1 Overview
myCro is a function package based on FcP system, for controlling a hydraulic ex-
haust device by Bosch Rexroth called "myCro", which controls speed variable
pump to adjust hydraulic fluid in constant pressure for gas exhausting. myCro
swithes pump on / off for degassing automatically according to gas content
feedback.
In FcP default setting, the myCro function package is not active. This myCro spe-
cialized function can be activated by setting F1.20 = 4.
7.12.2 Load myCro Configuration
The following table shows the parameters will be mostly used for myCro func-
tion. Part of the parameters have different values in FcP default and myCro de-
fault, these will be set to myCro default by setting F1.20 = 4.
Code
Name Setting range
FcP
default
myCro
default
F1.04
Pressure command selec-
tion
0: Pressure command digital setting
0
1: Pressure command digital setting
1
2: Pressure command digital setting
2
3: Pressure command digital setting
3
0 0
F1.05...
F1.08
Pressure command 0.0...1,000.0 bar 10.0 160.0
F1.12
Flow command digital set-
ting
0...5,000 rpm 400 2500
F1.13
Flow command digital set-
ting 1
0...5,000 rpm 400 400
F1.14 Flow command selection
0: Flow command digital setting 0
1: Flow command digital setting 1
0 0
F1.20
CytroPac parameter initiali-
zation
0: No selection
1: CytroPac basic
2: CytroPac advanced
3: CytroPac premium
4: myCro
0 0