Code Name Setting range
FcP
default
myCro
default
F1.21 CytroPac parameter display
0: No selection
1: CytroPac basic
2: CytroPac advanced
3: CytroPac premium
4: myCro
0 0
F2.00 Analog input AI1
0: No function assigned from ASF
1: Pressure command
2: Pressure feedback
3: Flow command
4: Oxygen feedback (for myCro)
0 0
F2.01 Analog input AI2 2 2
F2.02
External analog input EAI
(-10V...10V, 0...20mA)
0 4
F2.03
External analog input EAI2
(-10V...10V, 0...20mA)
0 0
F2.10 Pressure sensor type
0: Others
1: HM20-2X/10-C
2: HM20-2X/50-C
3: HM20-2X/100-C
4: HM20-2X/160-C
5: HM20-2X/250-C
6: HM20-2X/315-C
7: HM20-2X/400-C
8: HM20-2X/630-C
9: Other 4...20 mA pressure sensor
10: Reserved
11: HM20-2X/10-H
12: HM20-2X/50-H
13: HM20-2X/100-H
14: HM20-2X/160-H
15: HM20-2X/250-H
16: HM20-2X/315-H
17: HM20-2X/400-H
18: HM20-2X/630-H
19: Other 0...10 V pressure sensor
3 5
F2.16...
F2.25
Digital input
0...21: See tab. 8-2 "Parameter list
of group F2" on page 66
22: Drive enable for myCro
0
F2.16 = 22,
others = 0