7.3 Pressure Command Processing
Pressure command can be generated from multiple sources such as predefined
in the parameters, analog input or fieldbus communication. User needs to define
the pressure command source prior to start up the system.
Fig. 7-4: Pressure command processing
Code Name Setting range Default Min. Attri.
F1.03 Pressure command source
0: Depend on the value of
F1.04
1: Select by digital input
(F1.04 shows status)
2: Analog input
3: Communication
0 - Stop
F1.04 Pressure command selection
0: Pressure command digital
setting 0
1: Pressure command digital
setting 1
2: Pressure command digital
setting 2
3: Pressure command digital
setting 3
0 - Run
F1.05 Pressure command digital setting 0 0.0...1,000.0 bar 10.0 0.1 Run
F1.06 Pressure command digital setting 1 0.0...1,000.0 bar 10.0 0.1 Run
F1.07 Pressure command digital setting 2 0.0...1,000.0 bar 10.0 0.1 Run
F1.08 Pressure command digital setting 3 0.0...1,000.0 bar 10.0 0.1 Run
Bosch Rexroth AG
Block Diagram of Main Functions
FcP 5020
22/83