troller to determine if it is an ''oil level error'', ''oil temperature error'' or even ''oil
level or temperature error'' if both or no warning is available.
''13: Oil level warning inverse'' and ''14: Oil level / temperature error inverse'' are
inversed evaluation from ''7: Oil level warning'' and ''12: Oil level / temperature
error'', i.e. true signal for no warning, and false signal for warning. Signal has
been inversed for wire broken monitoring.
All warning and error information are presented by d0.88 and d0.89, see chapter
8.7 "Monitoring Parameter" on page 75.
FcP 5020 Bosch Rexroth AG
Block Diagram of Main Functions
DOK-RCON03-FCP5020****-QU04-EN-P
53/83