Version 4.0
2024-03-27
BOSCHE Weighing Systems
Page 39
Weighing Terminal EWI / MWI Operation | 4
4.12.3 Quick menu - short description
Note
The Quick menu is used for simplified input or reading out of parameters and
parameterization of the display. In the Quick Menu parameters to operate at
check-weighing, the alibi memory, the printer and backlight and automatic
shutdown can be set.
Menü Untermenü Optionen Funktion
AO1
HiLoGo
Set limit
values
A01-00
bEEP
Setting the
acoustic signal
for tare weigh-
ing.
oFF
Acoustic signal is deactivated.
8E Ok
Acoustic signal: Weigh within
the selected limits.
8E Lo
Acoustic signal: Weigh below
the selected limits.
8E Hi
Acoustic signal: Weigh above
selected limits.
8EHiLo
Acoustic signal: Weigh below /
above the selected limits.
A01-01
STore
Saving the limit
values (HLG-
Mode)
off
„HI“ and „Lo“- limit values must
be set again after a power reset.
on
„HI“ und „Lo“- limit values are
stored.
a01-03
LIGHt5
Brightness
„10" --> Enter the value
using the keys <UP> and
<LEFT>
Brightness 0 - 100 %
Settings for the brightness of
the signal light LEDs.
Brightness controll in 5 steps.
5 = dim
100 = brightest level
A02
MEmorY
Sum
memory
No function in version 4.0.
A03
ALIbI
Query alibi
number
Ed “
0“ flashing --> Enter
the value using the keys
<UP> and <LEFT>
Enter the Alibi number to query
the stored alibi values