Page 77
BOSCHE Weighing Systems
Version 4.0
2024-03-27
5 | Function menu (advanced functions) Weighing Terminal EWI / MWI
5.2.4 Function menu P05 - overview filter
It is possible to set the internal measuring rate of the AD converter here. This
parameter directly influences further settings of the weighing operation.
With increased measuring rates, the scales operates faster but looses stability.
Lower measuring rates improve stability but reduce the speed. We recommend
using lower measuring rates in an environment with a lot of motion.
The following measuring rates can be selected: 6, 12, 25, 50, 100 and 200.
F1LTER
PAoF1L
SPS
Wnd
ATT
F05
F05-01
F05-03
F05-02
F05-04