Page 61
BOSCHE Weighing Systems
Version 4.0
2024-03-27
5 | Function menu (advanced functions) Weighing Terminal EWI / MWI
This is the symbol used in this manual for “Verification invalid”
F05
FILTER
Filter
F05-01
PAoFIL
Profil
0
1
2
Profil 0 (default)
Profil 1 (animal weighing func-
tion)
Profil2 (quikly weighing)
F05-02
5P5
Sampling rate
6
12
25
50
100
200
Sampling rate-values
F05-03
Wnd
Delay
0,....99
Delay values for filling the filter
(default 0).
F05-04
ATT
Attenuation
0.....10
Attenuation values (default 2).
F06
LE9AL
Legal
f06-01
ALIBI
Alibis memory
ALB.5W
AL.OFF
AL.ON
Alibi memory on / off
ALB.5HW
ED. 0 flashes
Enter the alibi number.
f06-02
TAc
Verification
TAC counter
f07
CoDE
- - - -
Password entry
(Passwort 0000)
Entry into calibration menu.
Attention
Once the verification counter is increased, the verification becomes null and
void.
Menu Submenu Option Function