B Series Degreaser Introduction
Rev G Page 17
• Move over the ultrasonic sump.
• Lower into the Ultrasonic Sump if the ultrasonic dwell time is greater than 0.
• Clean with or without ultrasonics for a specified time.
• Rise to the Vapor Zone.
• Move over the Boiling Sump
• Spray for a specified time if the degreaser is equipped with spray manifolds.
• Dwell for a specified time in the Vapor Zone.
• Open the cover if equipped with a working mode cover
• Rise to the Freeboard Zone.
• Dwell for a specified time in the Freeboard Zone.
• Rise to the fully up position.
• Signal that the cycle is complete.
• Close the cover.
The lift may also be raised or lowered or moved left or right in the manual mode.