B Series Degreaser Operation
Rev G Page 76
The display will show CYCLE DONE as shown in Figure 4-17.
Figure 4-17 Cycle Complete Screen
The power cover will close.
4.4.5 Aborting Cycle
The cycle may be aborted by pressing CYCLE STOP or by moving the lift in the Manual
Mode.
4.4.5.1 Cycle Stop
Press CYCLE STOP to stop the cycle. CYCLE STOPPED will be displayed:
4.4.5.2 Manual Up or Manual Down
Moving the lift in the Manual Mode aborts the cycle. The cycle cannot be restarted
without returning to the LOAD/UNLOAD position after this interruption.
The appropriate Manual Moving, Lift Ready or Lift Not Ready message will be displayed
after the cycle is aborted.
4.4.6 Timeout Errors
If a movement step times out before the destination is reached, a timeout error message is
displayed and the cycle is aborted. The lift must be returned to the LOAD/UNLOAD position
before restarting the cycle. Determine the cause of the error before restarting the cycle.
4.4.7 Restarting Aborted Cycle
4.4.7.1 Lift Moved
Return the lift to the LOAD/UNLOAD position before restarting the cycle.
4.4.7.2 Lift Not Moved
The cycle may be resumed by pressing both START switches if the lift has not been
moved. The step timer will be reset to the set time.
4.4.8 Changing Dwell Times While Cycle is ON
Time settings may be changed while the lift is in operation.