6-7
Troubleshooting flow chart - sheet 4
Yes Yes Yes
No No No
Yes Yes
No No
Yes
No
Yes
No
Yes
No
Check all sealant
locations and look
for air bypassing
the filter
9
Check I/O board &
wire connections
Does basket stay
down until Cook
cycle ends?
Does basket rise at
the end of the
Cook cycle?
Does product cook
without undue
odor?
Check microswitch
and wire
connections
Check speaker
connections
between controler
and I/O board
Change
or flter
oil
Does oil need to be
filtered or
changed?
Does Air Filter
need to be
replaced?
Replace
Air Filter
Does Timer start
when basket
lowers?
No
Problem
Adjust "Up/Down"
microswitch or
motor location
Is "Down"
microswitch closed
completely?
Does short stud on
lift motor engage
Up/Down
microswitch?
Adjust disk and
tighten set screw
broaster.com Manual #16501 7/06 Rev 2/15