278580 Revision A 97
LF80C ZeniD RFID Reader 7 Operation
Product Manual 7.3 Operation of SECS Protocol
Parameter 24 (0x18) r/w max repeat
If a read/write error occurs, this parameter defines the maximum number
of attempts to read or write a transponder.
0 .. 255
Default: 5
Parameter 25 (0x19) Transponder type
This parameter defines the validity of the read transponder data.
00 ... Read and write TIRIS type
Each transponder page consists of 8 data bytes. The validity of the
data bytes is checked by a 2 byte CRC checksum.
Default: 00
Parameter 26 (0x1A) Sensor activity
The RFID reader offers the option of deactivating the connected sensor.
0 Sensor not activated
1 Sensor activated
Default: 1
Parameter 27 (0x1B) Watchport for presence sensor
Enables a message to the host if a cassette/FOUP is detected on the I/O
port, or if it is removed from the I/O port.
A sensor is required to use this option.
0 Report nothing
1 Report cassette/FOUP is removed
2 Report cassette/FOUP is detected
3 Report cassette/FOUP is detected and cassette is removed
Default: (3) Report cassette/FOUP is detected and removed
Parameter 28 (0x1C) Transmitter level (read mode)
The intensity of the field strength to load a transponder during a read
process.
The default value (1) should not be changed.
0 Reduced field strength
1 Maximum field strength
Default: (1) Maximum field strength