EasyManua.ls Logo

Brooks LF80C - SECS-I Message Examples

Brooks LF80C
180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Brooks Automation
122 278580 Revision A
7 Operation LF80C ZeniD RFID Reader
7.3 Operation of SECS Protocol Product Manual
7.3.10 SECS-I Message Examples
All examples are produced with the default gateway-ID 255 (decimal) or
0x00FF (hexadecimal)!
S1F1 Message from the reader to the host
Reader to Host: S1F1
10:30:47 Incoming: ENQ ( 05 )
10:30:47 Outgoing: EOT ( 04 )
10:30:47 Incoming: Length Byte ( 0A )
10:30:47 Incoming: Header ( 81 FF 81 01 80 01 00 01 00 01 )
10:30:47 Incoming: Checksum ( 02 85 )
10:30:47 Outgoing: ACK ( 06 )
Host to Reader: S1F2
10:30:47 Outgoing: ENQ ( 05 )
10:30:47 Incoming: EOT ( 04 )
10:30:47 Outgoing: Length Byte ( 10 )
10:30:47 Outgoing: Header ( 01 FF 01 02 80 01 00 01 00 01 )
10:30:47 Outgoing: Data ( 01 02 41 00 41 00 )
10:30:47 Outgoing: Checksum ( 0B 02 )
10:30:47 Incoming: ACK ( 06 )
S1F1 Message from the host to the reader
Host to Reader: S1F1
10:29:00 Outgoing: ENQ ( 05 )
10:29:00 Incoming: EOT ( 04 )
10:29:00 Outgoing: Length Byte ( 0A )
10:29:00 Outgoing: Header ( 01 FF 81 01 80 01 00 00 00 01 )
10:29:00 Outgoing: Checksum ( 04 02 )
10:29:00 Incoming: ACK ( 06 )
Reader to Host: S1F2
10:29:00 Incoming: ENQ ( 05 )
10:29:00 Outgoing: EOT ( 04 )
10:29:00 Incoming: Length Byte ( 1C )
10:29:00 Incoming: Header ( 81 FF 01 02 80 01 00 00 00 01 )
10:29:00 Incoming: Data ( 01 02 41 06 52 53 72 64 30 31 41 06 56 )
10:29:00 Incoming: Data ( 31 2E 30 2E 30 )
10:29:00 Incoming: Checksum ( 05 B5 )
10:29:00 Outgoing: ACK ( 06 )

Table of Contents