Brooks Automation
100 278580 Revision A
7 Operation LF80C ZeniD RFID Reader
7.3 Operation of SECS Protocol Product Manual
Parameter 37 (0x25) MID area
This parameter defines the range of the MID.
'0' … '10' pages
Default: '2' - MID area = 2 pages = 16 bytes (depends on
Parameter 25
(0x19)).
Parameter 38 (0x26) Test after software reset
This parameter enables/disables the initial test after a software reset.
0 No initial test after software reset
1 Initial test after software reset
Default: (0) No initial test after software reset
Parameter 39 (0x27) Transmitter level (write mode)
The intensity of the field strength to load a transponder during a write
process. The default value (1) should not be changed.
0 Reduced field strength
1 Maximum field strength
Default: (1) Maximum field strength
Parameter 40 (0x28) Transponder load duration (write mode)
The time required to load a transponder during a write process.
The default value (50 ms) should not be changed.
00 .. 255 ms
Default: (50) 50 ms
IMPORTANT
See also
Parameter 42 (0x2A) -
Parameter 45 (0x2D) and
Parameter 99 (0x63).