278580 Revision A 103
LF80C ZeniD RFID Reader 7 Operation
Product Manual 7.3 Operation of SECS Protocol
Parameter 45 = ’0’
Tag memory:
Output string: '123456789ABC'
Parameter 45 = ’1’ or ’2’
Tag memory:
Output string (parameter 45 = ‘1’): ‘0000123456789ABC’
Output string (parameter 45 = ‘2’): ‘123456789ABC’
Default: 0
Parameter 99 (0x63) Customer code
If the customer requires special parameter settings that deviate from the
default values, a customer code can be assigned by BROOKS to set several
parameter values via one parameter.
The following parameters are defined:
'00' Sets the following parameters:
Reader complies with the last revisions of SEMI E99-0303
'03' Sets the following parameter:
Reader complies with older reader versions before the revision of
SEMI E99-0303.
Page 2 9 A B C 0x00 0x00 0x00 0x00
Memory address 15 14 13 12 11 10 9 8
Page 1 1 2 3 4 5 6 7 8
Memory address 7 6 5 4 3 2 1 0
Page 2 0 0 0 0 1 2 3 4
Memory address 15 14 13 12 11 10 9 8
Page 1 5 6 7 8 9 A B C
Memory address 7 6 5 4 3 2 1 0
Parameter Value
37 2
42 0
43 16
44 1
45 0