EasyManua.ls Logo

Brooks LF80C - Page 129

Brooks LF80C
180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Brooks Automation
278580 Revision A 117
LF80C ZeniD RFID Reader 7 Operation
Product Manual 7.3 Operation of SECS Protocol
S18F3: WRITE ATTRIBUTE REQUEST (WAR) (host -> reader,
reply)
This message requests the subsystem to set the value of the read/write
attributes of the component specified in the TARGETID.
S18F3 ,W
L,2
1. <TARGETID>
2. L,n
1. L,2
1. <ATTRID1>
2. <ATTRVAL1>
n. L,2
1. <ATTRIDn>
2. <ATTRVALn>
S18F4: WRITE ATTRIBUTE ACKNOWLEDGE (WAA) (reader ->
host)
This message acknowledges the success or reports the error of the request
to write attribute data to the subsystem indicated in the TARGETID.
S18F4
L,3
1. <TARGETID>
2. <SSACK>
3. L,1
L,s
1. <STATUS1>
s. <STATUSs>
If the ATTRID of the S18F3 message is unknown, a communication error
(CE) occurs.

Table of Contents