VI-15
M-12 "55 HIGH VOL MALF" is displayed (Faulty output from the H.V.P.S. ASSY)
Possible cause Step Check Result Remedy
Main PCB 1 When a test print is carried out, is the voltage
of the each pin in the main PCB connector P6
turned on and off as the below list?
No Replace the main PCB
assy.
Pin No. Signal name Voltage
(reference
value)
Remarks
HVHALFN 0.0 ~ 10.0V
HV harness 2 Is the voltage of the each pin of the high-
voltage power supply PCB connector P2
No Replace the HV harness.
High-voltage
power supply
PCB
turned on and off? Yes Replace the high-voltage
power supply PCB assy.