2-57
Confidential
Error code E000
An error occurred in the ROM check sum.
Error code E100
Program error
Error code E500
An error occurred during access to the DRAM in the main PCB ASSY.
Error code E600
Write error in the EEPROM of the main PCB ASSY
Error code E701
Irregular operation of the flash ROM file system on the main PCB.
Error code E702
Read error in the flash ROM on the main PCB
Error code F900
The country code was not entered correctly.
Print Unable E0
Turn the power off and then back on again.
Print Unable E1
Turn the power off and then back on again.
<User Check>
Install the latest firmware.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Print Unable E5
Turn the power off and then back on again.
Print Unable E6
Turn the power off and then back on again.
Print Unable E7
Turn the power off and then back on again.
Print Unable E7
Turn the power off and then back on again.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Machine Error F9
-
Step Cause Remedy
1
The power was turned OFF while
function code 74 was running.
Reenter the country code.
2
Main PCB failure Replace the main PCB ASSY.

Table of Contents

Other manuals for Brother HL-L2300d Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brother HL-L2300d Series and is the answer not in the manual?

Brother HL-L2300d Series Specifications

General IconGeneral
FunctionsPrint
Standard Paper Capacity (sheets)250
Standard Interface(s)USB 2.0
Print Resolution (maximum dpi)2400 x 600 dpi
Recommended Monthly Print Volume250 - 2, 000 pages
Operating System CompatibilityWindows, Mac, Linux

Related product manuals