WSW01 (Dial pulse setting)
Selector
No.
Function Setting and Specifications
1
2
Dial pulse generation mode
No. 1 2
00 : N
01 : N+1
1 0 : 10-N
11 : N
3
4
Break time length in pulse dialing
No. 3 4
0 0 : 60 ms
0 1 : 67 ms
1 0 : 40 ms (for 16 PPS)
1 1 : 64 ms (at 106-ms intervals)
5
6
Inter-digit pause
No. 5 6
0 0 : 800 ms
0 1 : 850 ms
1 0 : 950 ms
1 1 : 600 ms
7
Switching between pulse (DP) and
tone (PB) dialing, by the function
switch
0: Yes 1: No
8
Default dialing mode, pulse (DP) or
tone (PB) dialing
0: PB 1: DP
Selectors 1 and 2: Dial pulse generation mode
These selectors set the number of pulses to be generated in pulse dialing.
N: Dialing "N" generates "N" pulses. (Dialing "0" generates 10 pulses.)
N + 1: Dialing "N" generates "N + 1" pulses.
10 - N: Dialing "N" generates "10 - N" pulses.
Selectors 3 and 4: Break time length in pulse dialing
These selectors set the break time length in pulse dialing.
(Example: If "1," "2," and "3" are dialed when N is set by selectors 1 and 2.)
Selectors 5 and 6: Inter-digit pause
These selectors set the inter-digit pause in pulse dialing.
(Example: If "1," "2," and "3" are dialed when N is set by selectors 1 and 2.)