42 Sync Pre-Installation
TEL-E-FOUL
Electrical Information
VOLTS HERTZ AC/DC PHASE AMPS WATTS
BRANCH
CIRCUIT
CUSTOMER
RESPONSIBILITY
BRUNSWICK
RESPONSIBILITY
120 50/60 AC 1 1.5 120
ON/OFF
SWITCH
OUTLET
TO SU PP LY
FEEDER WIRING
AND “J” BOX AND
LOW VOLTAGE
CONTROL.
CUSTOMER/
ELECTRICIAN TO
CONNECT.
TO SUPPLY AND
INSTA LL TEL-
E-FOUL AND
POWER CABLE
TO “J” BOX.
230 50/60 AC 1 .75 120
Circuit Requirements - Tel-E-Foul
WIRES
PER
CIRCUIT
UNITS PER
CIRCUIT
WIRE SIZE BREAKER SIZE RECEPTACLE SUPPLIED BY BRUNSWICK
3 UP TO 10 12 GAUGE 20 A NO
Receptacle Location Tel-E-Foul
ONE JUNCTION BOX BELOW THE TEL-E-FOUL UNITS ON EACH BALL RETURN NEAR THE FOUL LINE
NOTE:Oneon/offswitchperTel-E-Foul.
CUSTOMER’S RESPONSIBILITY: THE CUSTOMER MUST PROVIDE ELECTRICAL POWER SOURCE THAT COMPLIES
WITH LOCAL CODE.