52 Sync Pre-Installation
Equipment Operating
Voltage
Frequency
(Hertz)
AC
or
DC
Phase Max amps
per Unit
@120 VAC
Max Amps
per Unit
@240VAC
Wires
per Fused
Circuit
Power
Consumption
(Watts)
Connector
(Female)
Supplied by
Customer
Special Notes
Peripheral
Controller
100-130 50/60 AC 1 1 - 3 120 120 Volt Outlet
2 Outlet
200-240 50/60 AC 1 - 0.5 3 120 230 Volt Outlet
Sync Tablet Power
Supply
100-130 50/60 AC 1 2 - 3 240 120 Volt Outlet
Outlet Shared with Peripheral
Controller
200-240 50/60 AC 1 - 1 3 240 230 Volt Outlet
HD Video
Distribution Center
100-130 50/60 AC 1
.5 Per
Modulator
- 3
60 (max)
Per Modulator
120 Volt Outlet
-
200-240 50/60 AC 1 -
.25 Per
Modulator
3
60 (max)
Per Modulator
230 Volt Outlet
Curtain Wall or
Overhead Switch
120 50/60 AC 1 1..2 - 3 144 120 Volt Outlet
Outlet Shared with Peripheral
Controller
240 50/60 AC 1 - .6 - 144 230 Volt Outlet
Client Computer
100-130 50/60 AC 1 5 - 3 600 120 Volt Outlet
-
200-240 50/60 AC 1 - 2.5 3 600 230 Volt Outlet
Server Computer
100-130 50/60 AC 1 6 - 3 960 120 Volt Outlet
500 VA UPS Supplies Power
200-240 50/60 AC 1 - 3 3 960 230 Volt Outlet
Point of Sale
Terminal
100-130 50/60 AC 1 12 - 3 1440 120 Volt Outlet
4 Outlet
200-240 50/60 AC 1 - 6 3 1440 230 Volt
Credit Card Device
100-130 50/60 AC 1 .75 - 3 90 120 Volt
2 Outlet
200-240 50/60 AC 1 . .38 3 90 230 Volt