Please read the following safety precauons to ensure proper
use of your generator. If the equipment is used in a manner not
specied, the protecon provided by the equipment may be
impaired.
To Prevent Hazard or Injury
Use Proper Line Cord
Use only the specied line cord for this product and make sure
line cord is cered for country of use.The operang voltage range
for the ECM 630 system is 100–240 vac, 50/60 Hz.
Ground the Product
This product is grounded through the grounding conductor of the
power cord. To avoid electric shock, the grounding conductor must
be connected to earth ground. Before making any connecons
to the input or output terminals of the product, ensure that the
product is properly grounded.
Make Proper Connecons
Make sure all connecons are made properly and securely. Any
signal wire connecons to the unit must be no longer than
three meters.
Observe All Terminal Rangs
Review the operang manual to learn the rangs on all
connecons.
Use Proper Fuse
Use only specied fuses with product.
Avoid Exposed Circuitry
Do not touch any electronic circuitry inside of the product.
Do Not Operate with Suspected Failures
If damage is suspected on or to the product do not operate
the product. Contact qualied service personnel to perform
inspecon.
Orient the Equipment Properly
Do not orient the equipment so that it is dicult to operate the
disconnecon device.
Place Product in Proper Environment
Review the operang manual for guidelines for proper operang
environments.
Observe All Warning Labels on Product
Read all labels on product to ensure proper usage.
Caution Risk of
Electric Shock
Caution
Protective Ground
Terminal
High Voltage Risk
These instruments contain a high voltage power supply adjustable
to 3,000 V. High voltage power supplies present a serious risk of
personal injury if not used in accordance with design and/or use
specicaons, if used in applicaons on products for which they
are not intended or designed, or if they are used by untrained or
unqualied personnel.
• The user must read this manual carefully before the
instruments are placed into operaon.
• Removing the cover will void the warranty.
• Do not connect or disconnect the high voltage cable with
the high voltage enabled.
• To connect or disconnect the cable, turn line power o and
unplug line (mains) cord.
• Do not touch the electrode p while the waveforms are
being applied.
If there are any quesons about the operaon of this instrument,
call BTX Customer service at 1-800-272-2775, or 1-508-893-8999.
Cauon Noce
The ECM 630 Exponenal Decay Wave Electroporaon System is
intended for laboratory use only and can be used in research and
development applicaons. These systems have been designed
to meet the standards for electromagnec compability (EMC)
intended for laboratory equipment applicaons as well as the
applicable safety requirements for electrical equipment for
measurement, control, and laboratory use. The unit itself does
not generate waste, but may be used to treat samples that are
hazardous. Please use appropriate PPE and ensure disposal in
accordance with local regulaons and pracces.
This product should not be used in the presence of a ammable
atmosphere such as an anesthec mixture with air, oxygen, or
nitrous oxide.
Safety Information