Routine Maintenance
124
V50 • V65 • V80 Operator’s Guide
Daily Maintenance - This can be carried out by a suitably trained operator.
Check the following items:
1. Oil level in hydraulic reservoir - top up if required.
2. Oil cooler radiator is not obstructed. Always clean from fan-side to outside.
3. Chassis engine air cleaner - service when shown by restriction indicator.
4. Mesh screens in body are clean and fitted correctly.
5. Centre baffle is in position - duals only.
6. Mechanical damage to brush gear and report damage to supervisor.
7. Brushes for adjustment and wear - adjust or replace as required.
8. Spray jets for correct operation - clean if necessary.
9. Liquid leakages.
10. Chassis items as recommended in chassis manufacturer’s handbook.
Weekly Maintenance - This can be carried out by a suitably trained operator.
Attend to/check the following:
1. Oil level in ‘HYDRODRIVE’ gearbox - top up if required.
2. Powapak bay is clean of oil etc.
3. Suction fan impeller, wear plates and intake flap for wear, renew if necessary.
4. Routing of electric and hydraulic services for chafing.
5. Lubricate all grease points - see page 136.
6. Water pump suction filters - see pages 18 and 124.
7. Oil level and condition in Supawash pump if fitted.
50 Hour Service - To be carried out by workshop personnel.
Attend to/check the following:
1. Change hydrodrive gearbox oil.
2. Renew transmission pump filter.
3. Drain and refill Supawash pump (if fitted).
1
st
Vh - Single Engine
NOTICE
Attention is drawn to the recommendations in the Auxiliary Engine Handbook.