GasAlertMax
Specifications
47
D1430/2 English
Display: Alphanumeric liquid crystal display (LCD)
Backlight: Automatically activates whenever there is
insufficient light to view the display and during alarm
conditions
Self-test: Initiated at activation
Calibration: Automatic Zero and Automatic Span
Oxygen Sensor: On Activation (auto)
User Enable/Disable Options:
Confidence Beep, Latching Alarms, Password Protect,
Sensor Disable
Batteries: Two Black & Decker VersaPak™ batteries
Battery Charger: Black & Decker VersaPak™ VP130
charger
Battery operating time: NiMH: 10 hours
First-time charge: NiMH: 12 hours for 2 batteries
Normal charge: NiMH: 12 hours for 2 batteries
Approvals:
Approved by CSA to both U.S. and Canadian Standards.
Approved: Class I, Division 1, Group A, B, C, and D;
Class I, Zone 0, Group IIC
Cenelec (LCIE): EEx ia d IIC
ATEX: 02 ATEX 6103X
AUS: Ex ia s IIB Ambient 40 °C
BAM performance verification to EN 50054 and EN 50057 for
the measurement of methane and to EN 50104 for oxygen,
according to expert opinion BAM II-468/2002 for apparatus
with implemented software version “Code D” (MX2-D).