GasAlertMax
User Manual
48
D1430/2 English
General Specifications for Datalogger Units*
Media Type: MMC (MultiMediaCard)
Size: 16 MB (standard); 16, 32 and 64 MB cards available
Storage: 250,000 lines of data (16 MB)
2.2 months (based on a normal work week)
Memory Type: Wrap-around memory ensures most recent
data is always saved
Sample Rate: One reading every 5 seconds (standard)
Data recorded: All sensor readings, all alarm conditions,
calibrations, event flags, battery status, sensor status,
confidence activation, sampling pump status, and product
status along with the time and date for each reading and unit
serial number.
MMC Card Test: Automatically on activation
* not part of BAM certification
GasAlertMax with Black Box Datalogger
Operation: Requires no user intervention
Continuous: Full time continuous datalogging while the
detector is operating
Access: Data cannot be accessed or manipulated by the
user
Data Retrieval: Authorized factory representative if required
Advise Indicators: Icon advises datalogger operating status
Card Alarm: MMC Card fail or missing