CAUTION
The installation and connection of the BWT MANAGER CONNECT DUO equipment should only be carried
out by trained and qualified personnel.
The installation must comply with the applicable standards and safety regulations!
CAUTION
Always switch off the mains supply before switching on the device or manipulating the outputs.
Never open the unit when it is powered up!
Maintenance and repairs must only be carried out by authorised and qualified personnel.
4.1 Choice of installation site
To ensure the safety of users and the proper operation of your BWT MANAGER CONNECT DUO, please
observe the following guidelines for installation:
➢ The cabinet must be located at a distance from the pool in accordance with the regulations applicable
at the installation site
➢ The appliance must be protected from frost and direct sunlight.
➢ The ambient temperature should be between 0 and 50°C
➢ The installation site must be properly ventilated, in particular to avoid corrosive atmospheres and
environments with high concentrations of solvent vapours
➢ Choose an installation site that is free of vibration, on a stable, solid, clean and undistorted surface
(level).
➢ The location of the cabinet must be compatible with the location of the product treatment tanks and
the injection points of the products in the hydraulic circuit: note the length of the tubing and follow
the instructions below
In case of non-compliance with these instructions :
➢ The unit may be damaged
➢ Measurements can be disrupted
➢ The guarantee shall be void!
4.2 Wall-mounting of the cabinet
1. Turn off the general power supply
2. Check that the filter pump is switched off.
3. Close the hydraulic valves and set the filter valve to "closed".