In advanced menu-> Advanced features
2023/03 - Revision index: A - Code: 0000139233
Menu 1D Chlorine probe
1D1: 1 Point: 1 point calibration using an external reference
instrument (photometer...).
1D2 (*): 2 Points: 2-point calibration using an external reference
instrument (photometer...).1D3:
Reset (Calibration): to cancel the calibration and restore the default
Chlorine probe settings.
(* sub-menu only available for open cell amperometric probes)
5.6 Setup menu
Menu consisting of the following 4 sub-menus:
2A: pH pump
2B: redox pump* / redox measurement**
2C: Chlorine pump**
2D: Alarm relay
- * BWT Manager connect Duo pH+Redox
- ** BWT Manager connect Duo pH+Redox+CL
The displays for the different models are as follows:
BWT Manager connect Duo pH+REdox
:
BWT Manager connect Duo pH+Redox+CL
Details of the submenus of the "Settings" menu:
2A - "pH pump" submenu
2A1 Setpoint: target value for pH
2A2 Type:
Acid: the pump injects acid to lower the pH
Alca: the pump injects a basic product to increase the pH
2A3 OFA: "Over feed Alarm" = maximum continuous dosing time
before the alarm is triggered
2A4 ON time: duration of a pump injection sequence, adjustable
between 5 seconds and 3600 seconds (*)
2A5 OFF time: duration of a pump idle sequence,
adjustable between 5 seconds and 3600 seconds (*)
2A6 Alarm min : pH value below which the instrument goes into alarm
2A7 Alarm max : pH value above which the instrument goes into alarm
(* Time on and Time off are only available if set Type dosing settings= Timed)
_1D____Chlorine_________
► 1: 1 Point
2: 2 Points
3: Reset
01/03
_2______SETTINGS______
► A: pH probe
B: Redox measurement
C: CL Pump
D: Alarm relay
01/04
_2______SETTINGS_______
► A: pH Pump (P1)
B: Redox pump (P2)
C: Alarm Relay
01/03
_2_____ SETTINGS _______
► A: pH pump (P1)
B: Redox measurement
C: CL Pump (P2)
D: Alarm relay
01/04
_2A______pH pump_____
► 1: SetPoint 7.40pH
2: Type
Acid
3: OFA 00’
4: Time On 00’
5: Time Off 00’
6: Alarm min 6 pH
7: Alarm max 8 pH
01/07