4.3 Installation of tapping saddles for probes ("free-standing" version) and product
injections
Recommended for installation as a "free-standing" version:
In order for the values measured by the probes to be as representative as possible of the water in the
pool, the probes should be positioned between the pump discharge and the inlet to the filter's multi-
way valve. In any case, they should be located before any heater and before the injection of chemicals.
The injection of chemicals should be done after all devices, just before the water is returned to the
pool.
It is possible to mount the tapping saddles on a bypass circuit in order to isolate them hydraulically for easier
and faster removal of the probes ("no water pressure") and to leave the filtration running (especially during
active wintering).
Installation diagram for pH - Redox systems
1
3
4
5
2
1. Buffer tank (if overflowing)
2. Filtration pump
3. Filter
4. Heating
5. Swimming pool

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BWT Manager Connect Duo and is the answer not in the manual?

BWT Manager Connect Duo Specifications

General IconGeneral
BrandBWT
ModelManager Connect Duo
CategoryController
LanguageEnglish

Related product manuals