Fault Possible Cause Solution
Charging
stops midway
AC grid outage
During AC charging, if power supply resumes
after short-time outage of the external power
grid, BYD charging equipment will re-start
charging automatically and no re-connection of
the charging equipment is required.
Charging cable is not
connected properly
Verify that the charging connection cable is not
loosely connected.
Charging connection
switch is pressed
If the charging connection switch is pressed,
the charging will stop. The charging connection
should be connected again to start charging.
High-voltage battery
temperature is too high
or too low
If the instrument cluster shows that EV function
is limited, the charging will automatically
stop. Charge the vehicle when the battery
temperature returns to a normal level.
Vehicle or charging pile
failure
Verify that there is fault prompts for the charging
pile or the vehicle, and it is recommended
to contact a BYD authorized dealer or service
provider.
Charge Method
Before charging:
Check charging equipment and port
for cracks, wear, rust or obstructions.
Make sure connection is tight.
Make sure the port is clear of 󽗊uids or
dirt, and its metal terminals are not
rusty or corroded.
In any of these cases, do not charge,
under risk of short circuit or electric
shock.
Using Mode 2 Charging Cable*
1. Equipment Descriptions
Connect the vehicle to an outlet that
meets local standards to charge the
vehicle.
A household socket meeting local
standards must be used in order to
avoid line damage or tripping due to
high-power charging, which may e󽗈ect
the normal use of other devices.
This EV Mode 2 Charging Cable
includes a power plug (complying with
local standards), a charging connector,
a control box, and a charging cable.
The plug is connected to a standard
household power socket, and the
charging connector to the vehicle's
charge port.
Charging time: Refer to the charging
time message on the instrument
cluster.
WARNING
See "Charging Instructions" for
charging safety warnings.
The highest working temperature
allowed for the product is 50°C.
Store the product in a cool and
dry place when it is not in use.
When charging, do not place the
equipment in the trunk, under the
82