which could generate usual variations in fuel transportation (pellets), causing a ame raising or drapping with
a possible switching off at lower powers.
Depending on the type of pellets it could be necessary a parameters adjustment, please contact an
Authorized Assistance Service.
10
INSTALLATION
10.1 INTRODUCTION
The assembly position must be chosen depending on environment, outlet, chimney ue.
Check with local authorities if there are any restrictive regulations which regard the combustible air inlet,
room ventilation, fume exhaust system together with chimney ue and chimney pot.
The manufacturer declines any responsibility in case of installation which are not in compliance with current
regulations, in case of a wrong room ventilation system, in case of an electric connection which is not in
compliance with regulations and in case of a wrong use of the appliance.
Intallation, electric connection, operation test and maintenance must be carried out by an authorized and
skilled technician.
Check if there is the combustible air inlet.
Check the probable presence of other stoves or appliances which could depress the room (see EXTERNAL
AIR INLET page 9).
Check at switched on stove if there is the presence of CO in the room.
Check if the chimney has the necessary draught.
Check if during the fume passage all has been executed in safety (probable fume losses and distances from
ammable materials, etc.…).
The installation of the appliance must enable an easy access for appliance, fume exhaust pipes and chimney
ue cleaning.
The installation must enable en easy access to the electric connection plug (see ELECTRIC CONNECTION
page 15).
It is forbidden to install the stove in bedrooms, bathrooms and in rooms used for storing combustible materials
and in one-room ats.
The installation in one-room ats is allowed if they are in sealed chamber.
In any case the stove must not be installed in rooms where it can get in touch with water or water splashes
because this can cause burn hazards and short-circuit.
To install more appliances, the external air inlet must be correctly dimensioned (see EXTERNAL AIR INLET page
9).
10.2 OVERALL DIMENSIONS
Fig. 11 - General dimensions