ALARM CAUSE SOLUTION INTERVENTION
AL 8 - FAILURE
DEPRESS
Obstructed exhaust
The exhaust chimney is partially or totally obstructed. Call
en expert stove-repairer who executes a check from the
exhaust up to the chimney pot.
Fume fan out of order
The pellet can burn also thanks to the chimney ue
depression without the aid of the fan. Have the fume fan
immediately replaced. It can be noxious to health to let
the stove running without fan.
Obstructed connecting
nozzle
Clean the connecting nozzle.
Faulty pressostat Replace the pressostat.
Faulty electronic board Replace the mother board.
Extreme chimney lenght
Contact an expert stove repairer and check that the
exhaust chimney is in compliance with regulations: see
CHIMNEY FLUE page 5.
Advers whether
conditions
In case of strong wind there can be a negative pressure
to the chimney. Check and switch the stove on again.
The re door is not
correctly closed
Close the re door correctly and check if the gaskets are
broken.
Fire door microswitch
faulty or out of order
Replace the re door microswitch.
14.2 PROBLEM SOLVING
Before of every Authorized Technician intervention, the same Technician has the duty to
check if the parameters of the mother board correspond to those of the table you own.
In case of doubts regarding the use of the stove, please contact ALWAYS the Authorized
Technician on order to avoi irreparable damages!