Pay attention if the value is positive or negative..
11.7 AIR REGULATOR
The stove is provided with a back air regulator and must have the following parameters (written also on the back
of the stove):
Fig. 21 - Air regulator
• Air regulator entrance 12 mm to nominal power with a chimney ue of 11 Pa.
11.8 FAILED IGNITION
If the pellets do not burn, the failed ignition will be indicated by the alarm “FAILED IGNITION”.
• If the room temperature is lower than 10°C, the plug is not able to bear the ignition stage. To support it please
insert some pellets in the burning pot and a piece of burning relighter igniter material on the pellets (for
example relighters cubes).
After a failed ignition the burning pot must be empty from the amassed pellets, before
starting the stove up again.
• Too much pellets in the burning pot, or humid pellet, or sooty burning pot make ignition difcult and create
dense white smoke which is harmful to health and can cause explosions on the combustion chamber. It is
therefore necessary not to stand in front of the stove during ignition stage if dense white smoke is present.
If after some months the ame appears weak and/or orange colored or the glass tends
to blackens and the burning pot to become encrusted, clean the stove, clean the fume
conduit and the chimney ue.
11.9 POWER FAILURE
• After a black-out lower than 5 seconds, the stove turns back to the power which was settled.
• After a black-out of more than 5 seconds, the stove enters the “COOLING WAIT” phase. Completed this
phase, it starts automatically up with the different phases (see START UP page 18).
11.10 TEMPERATURE SETTING
• To modify the ambient temperature it is sufcient to press P1 and P2 keys according to the desired temperature
inside the menu “SET TEMP AMBIENT”.
• To see the set temperature, press once P1 key.
11.11 FUME TEMPERATURE
To check the fume temperature at the exhaust it is sufcient to keep pressed P2 key.
11.12 SWITCHING OFF
To switch the stove off, keep pressed P4 key: the display shows “FINAL CLEANING”. After about 10 minutes, also
the fume fan switches off (this happens always, independently if the stove is hot or cold). Then “OFF” will be
shown.